Steps to determine the correct emergency lighting in Australia

Exit and Emergency Lights

Steps to determine the correct emergency lighting in Australia follow a structured approach outlined by the Australian Standard AS 2293.1:2018. This standard provides essential guidelines for the inspection, testing, and maintenance of emergency lighting systems within various buildings.

Assessment of Building Layout: Commence by conducting a thorough assessment of the building layout. AS 2293.1:2018 emphasizes tailoring emergency lighting to suit the specific characteristics of each space, taking into account factors such as size, structure, and occupancy.

Identification of Escape Routes: Map out the primary escape routes within the building. Emergency lighting should be strategically placed along these routes to guide occupants to safety, aligning with guidelines outlined in the standard.

Determination of Lux Levels: Calculate the required illuminance levels (lux) for different areas within the building. AS 2293.1:2018 provides specific recommendations for illuminance levels, considering factors such as occupancy type and space function.

Selection of Emergency Lighting Types: Choose the appropriate types of emergency lighting based on the assessment and calculations. AS 2293.1:2018 distinguishes between self-contained emergency lights, central battery systems, and others, providing guidance on when each type is suitable.

Placement of Emergency Lights: Determine the optimal placement of emergency lights to achieve uniform illumination. AS 2293.1:2018 specifies the required spacing between luminaires to ensure consistent coverage along escape routes and in open areas within the building.

Consideration of Obstacles and Changes in Level: Account for any obstacles or changes in level that may affect emergency lighting effectiveness. Adjustments in luminaire placement and type may be necessary to overcome these challenges.

Verification of Compliance: Regularly verify that the selected emergency lighting system complies with AS 2293.1:2018. This involves ensuring that illuminance levels are maintained, lights operate correctly during tests, and any required signage is in place and visible.

Emergency Exit Signage: Integrate appropriate emergency exit signage into the emergency lighting plan. AS 2293.1:2018 provides guidance on exit sign design, placement, and visibility to enhance wayfinding during emergencies.

Documentation of Emergency Lighting Plan: Document the emergency lighting plan, detailing luminaire type, location, and spacing. This documentation serves as a reference for ongoing maintenance, testing, and compliance verification.

Installation by Competent Personnel: Ensure professional installation of the emergency lighting system by competent personnel. AS 2293.1:2018 highlights the importance of meeting safety standards and maintaining system reliability through proper installation.

Regular Maintenance Schedule: Establish a routine maintenance schedule for the emergency lighting system. AS 2293.1:2018 mandates inspections, testing, and servicing to address issues promptly and maintain compliance with safety standards.

Record-Keeping: Maintain detailed records of all maintenance activities, tests, and modifications to the emergency lighting system. Proper record-keeping is essential for audits, compliance verification, and addressing potential issues in the future.

Employee Training: Provide training on the proper operation and testing of the emergency lighting system. AS 2293.1:2018 emphasizes ensuring that individuals responsible for the system are familiar with its components and procedures.

Emergency Response Plan Integration: Integrate the emergency lighting plan with the overall emergency response plan for the building. This ensures a coordinated and efficient evacuation process during emergencies, as specified by AS 2293.1:2018.

Regular Review and Updates: Conduct regular reviews of the emergency lighting plan to account for changes in building layout, occupancy, or regulations. AS 2293.1:2018 encourages periodic reassessment to ensure the ongoing effectiveness and compliance of the emergency lighting system.

Testing Frequency: Implement regular testing of emergency lights according to the intervals specified in AS 2293.1:2018. This involves functional tests at six-month intervals and duration tests annually to ensure the lights' operational status and sustained illumination during emergencies.

Consideration of Different Types of Emergency Lights: Recognize variations in testing requirements for different types of emergency lights. AS 2293.1:2018 delineates distinct testing procedures for self-contained emergency lights and central battery systems, each tailored to their specific characteristics.

Emergency Lighting Zones: Understand the concept of emergency lighting zones within a building, as defined by AS 2293.1:2018. Properly categorize zones based on factors like occupancy type and function to determine the appropriate emergency lighting requirements for each zone.

Upkeep of Central Battery Systems: If utilizing central battery systems, adhere to specific maintenance procedures outlined in AS 2293.1:2018. This includes regular inspections, battery capacity tests, and assessments to ensure the overall reliability and performance of the central battery.

Adaptation to Evolving Technologies: Stay informed about advancements in emergency lighting technologies. AS 2293.1:2018 acknowledges the dynamic nature of technology and encourages the adoption of new and improved emergency lighting solutions to enhance safety and efficiency.

Collaboration with Authorities: Collaborate with local authorities responsible for building codes and safety regulations. AS 2293.1:2018 recommends consultation with these authorities to ensure that emergency lighting plans align with regional standards and regulations.

Continual Education and Training: Encourage continual education and training for personnel involved in emergency lighting. Keeping abreast of developments in emergency lighting technology and standards ensures that individuals remain competent and well-informed in their roles.

Enhancement of Emergency Lighting Strategies: Continually seek opportunities to enhance emergency lighting strategies within the building. AS 2293.1:2018 supports a proactive approach, encouraging building owners and managers to explore innovations that contribute to improved emergency lighting performance.

Integration of Emergency Lighting with Building Management Systems: Explore the integration of emergency lighting systems with building management systems where applicable. AS 2293.1:2018 recognizes the potential benefits of interconnected systems for monitoring, control, and more efficient emergency response coordination.

Adherence to Changing Regulations: Stay vigilant regarding updates to building codes and safety regulations. AS 2293.1:2018 acknowledges the dynamic nature of standards and recommends consistent monitoring to ensure ongoing compliance with the latest requirements.

Response to Specific Building Characteristics: Address specific characteristics of the building that may impact emergency lighting. Consider factors such as architectural features, materials, and occupancy patterns when determining the most effective placement and type of emergency luminaires.

Consideration of Evacuation Strategies: Align emergency lighting plans with overall evacuation strategies. AS 2293.1:2018 emphasizes the importance of integrating emergency lighting into broader evacuation plans, ensuring a seamless and efficient process during emergency scenarios.

Emergency Lighting in Non-Occupied Spaces: Consider the requirements for emergency lighting in non-occupied spaces. AS 2293.1:2018 provides guidance on the necessity and specifications for emergency lighting in areas that may not be regularly occupied but are crucial for safe evacuation.

Periodic Review of Emergency Lighting Plans: Schedule periodic reviews of emergency lighting plans to account for changes in building use, layout, or occupancy. AS 2293.1:2018 recommends regular reassessment to maintain alignment with the building's evolving needs and characteristics.

Education of Occupants: Educate building occupants on the importance of emergency lighting and evacuation procedures. AS 2293.1:2018 underscores the significance of creating awareness among occupants to facilitate a safe and orderly evacuation in emergency situations.

Customization for Specialized Occupancies: Customize emergency lighting plans for specialized occupancies, such as healthcare facilities or industrial settings. AS 2293.1:2018 acknowledges the unique requirements of different occupancies and recommends tailoring emergency lighting strategies accordingly.

Preventive Measures for False Alarms: Implement preventive measures to minimize false alarms that may impact emergency lighting. AS 2293.1:2018 suggests strategies to reduce the occurrence of false alarms, ensuring that emergency lighting responds effectively to genuine emergency situations.

Collaboration with Emergency Services: Collaborate with local emergency services to align emergency lighting plans with broader emergency response initiatives. AS 2293.1:2018 recognizes the importance of coordination with emergency services to enhance overall building safety.

Disclaimer

This information is provided with the expectation that individuals will independently evaluate and validate all inforrmation with accredited experts. Exiting assumes no responsibility for any harm, losses, or damages resulting from the utilization or dependence on this information .